Specification LibraryLiterature LibraryContact Us

Sound Control Window Systems

QuietLite™ Series

Performance

Acoustical Performance Data
Sound Transmission Loss Data, dB
1/3 Octave Band Center Frequency, Hz 100 125 160 200 250 315 400 500 630 800 1K 1.25K 1.6K 2K 2.5K 3.15K 4K 5K STC
Model U                                      
U-4-43 25 27 28 32 36 36 39 40 43 45 50 52 49 41 41 46 52 55 43
U-11-51 37 36 37 36 40 42 46 47 51 55 57 59 57 54 57 58 59 59 51
Model HM                                      
HM-BRG-8-48 40 37 36 40 44 44 46 47 49 50 45 44 46 52 55 54 53 56 48
HM-11-53 39 34 40 39 43 46 51 52 53 55 54 54 57 60 64 66 67 67 53
HM-11-54 38 38 38 42 45 47 49 49 53 55 55 57 58 59 57 58 59 59 54
Model SF                                      
SF-11-57 - 42 43 48 48 52 54 55 56 54 53 57 58 59 59 61 62 - 57
All tests performed by Riverbank Acoustical Laboratories, an independent NVLAP accredited acoustical testing facility. The test method conforms with ASTM Designations E90-02 and E413-87.