Sound Transmission Loss Data, dB
Click below for specifications and drawings
| Octave Band Center Frequency, Hz |
125 |
250 |
500 |
1K |
2K |
4K |
STC |
Barrier Panels
|
|
|
|
|
|
|
|
| TYPE SL |
18 |
26 |
35 |
45 |
49 |
52 |
37 |
| TYPE SL-R |
18 |
26 |
35 |
45 |
49 |
52 |
37 |
| H/P 42 V-Stack |
23 |
31 |
40 |
49 |
56 |
62 |
42 |
| H/P 38 |
24 |
25 |
33 |
43 |
50 |
55 |
38 |
| H/P 42 |
23 |
31 |
40 |
49 |
56 |
62 |
42 |
| H/P 44 |
27 |
34 |
41 |
46 |
53 |
59 |
44 |
| H/H 50 |
26 |
44 |
50 |
54 |
57 |
64 |
50 |
| H/H 52 |
37 |
43 |
47 |
53 |
54 |
57 |
52 |
| All tests performed by Riverbank Acoustical Laboratories, an independent NVLAP accredited acoustical testing facility. The test method conforms with ASTM Designations E90-99 or E90-02 and E413-87. |
| Octave Band Center Frequency, Hz |
125 |
250 |
500 |
1K |
2K |
4K |
STC |
Sound Absorption Coefficients Barrier Panels
Click below for specifications and drawings |
|
|
|
|
|
|
|
| TYPE SL |
0.92 |
1.15 |
1.22 |
1.13 |
1.08 |
1.04 |
0.95 (1.15) |
| H/P 42 |
0.68 |
1.06 |
1.12 |
1.08 |
1.03 |
0.98 |
0.95 (1.05) |
| All tests performed by Riverbank Acoustical Laboratories, an independent NVLAP accredited acoustical testing facility. The test method conforms with the requirements of the ASTM Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method: ASTM C423-90a and E795-00. |